Key points
- Route every vendor session through a segmented, monitored remote-access path. NIST names segmentation and isolation as foundational for OT security.
- Give each engineer a unique credential, strong authentication, and a role limited to the job. NIST recommends role-based access control for this.
- Keep PLC-programming computers and portable engineering workstations inside the ICS area, per NIST.
- Log and monitor every remote session in near real time, and test changes in a sandbox before production when possible.
- NIST does not supply NDA wording or liability caps, so have counsel draft those terms around your deal.
Give forward deployed engineers access to your OT network only through a segmented, monitored remote-access path, never a flat connection to the plant floor. NIST identifies segmentation and isolation as foundational elements of OT network security. Pair that with unique credentials, strong authentication, role-based access limited to the job, and full session logging, then settle the contract terms with a lawyer before the first login.
What counts as OT, and who is a forward deployed engineer here?
NIST defines OT as programmable systems and devices that interact with, or manage devices that interact with, the physical environment. That covers PLCs, controllers, and the systems that configure them.
In this guide, a forward deployed engineer (or forward deployed security engineer) is an engineer who works near or inside your environment to implement, operate, or secure systems. That is a working definition, not an official government one. For the role itself, see our page on what a forward deployed engineer does and who hires them.
Which NIST guidance should you build on?
NIST SP 800-82 Rev. 3 provides guidance for securing OT while addressing performance, reliability, and safety requirements. It covers typical OT topologies, threats, vulnerabilities, and recommended countermeasures.
It also includes tailored security-control baselines for low-, moderate-, and high-impact OT systems. Decide which of those three impact levels fits each production area, then set vendor access rules to match. A packaging line and a system that controls a hazardous process should not share the same access policy.
How do you segment the network before a vendor connects?
Treat a vendor session as remote access, which NIST describes as access by users or systems communicating from outside an information-system security perimeter. NIST also describes remote-access points as distinct devices, areas, or locations used to configure control systems and access process data. Inventory yours first, because every one is a door you must control.
Then follow the pattern in NIST SP 1800-10. It describes cloud-based virtual desktops that traverse an enclave to reach a device deployed inside the local OT network. It also describes encrypted connections from the local OT network to the enclave that connects to the remote user's virtual desktop.
Teams often build this with a DMZ and a jump server, with the enclave playing that intermediary role. A practical build looks like this:
- Place the vendor entry point in its own enclave, separate from both the corporate IT network and the plant network.
- Have the vendor land on a virtual desktop inside that enclave, not on their own laptop.
- Let the virtual desktop reach only the specific OT devices named in the work order.
- Initiate encrypted connections from the OT side to the enclave, as the NIST example describes.
- Block every other path between the enclave and the control network.
How do you apply zero trust to an outside engineer?
NIST states that organizations may incorporate zero-trust principles into their OT security architecture. For a vendor, that means no standing trust because a person sits behind a vendor badge or a VPN.
NIST SP 1800-10 states that the described tools can control who accesses a manufacturing environment, what the user can access, and when access is allowed. Turn those three controls into a written access record for every engineer:
- Who: a named person with a unique account, never a shared vendor login.
- What: a role limited to the systems in the statement of work.
- When: a defined window tied to a scheduled task, closed afterward.
NIST SP 800-82 Rev. 1 recommends role-based access control to restrict ICS privileges to those required for a person's job. It also recommends stronger authentication in high-risk environments, including challenge-response or multifactor authentication using biometric or physical tokens. Require one of those for every vendor account that can touch a high-impact system.
What rules should apply to laptops and engineering workstations?
NIST states that PLC-programming computers and portable engineering workstations should remain inside the ICS area and should not be used outside the ICS network. Do not let a vendor treat a plant engineering workstation as a take-home machine.
The reverse is a sound rule too. Keep the vendor's own devices out of the control network, and have engineers work from the enclave's virtual desktop instead.
How do you log and monitor vendor sessions?
NIST identifies centralizing logging and network monitoring as OT security capabilities. For remote-control software, NIST SP 800-82 Rev. 1 recommends unique credentials, strong authentication, encryption where appropriate, audit logs, and near-real-time monitoring.
Set these as minimum requirements for every vendor session:
- Every login, command, and file transfer goes to a central log your team owns, not only the vendor.
- Someone on your side reviews alerts in near real time during active sessions.
- Logs stay under your control after the engagement ends.
How should vendor code reach the factory floor?
NIST states that patches should be tested in a sandbox or test environment before production deployment when possible. Apply the same discipline to vendor-written code and configuration changes.
A simple release path has three gates: test in a sandbox, review by your own controls engineer, then deploy during a window your operations team approves. The sources here do not prescribe a specific change-approval process, so match it to your safety procedures.
What contract, NDA, and liability terms should you settle?
The NIST material above supports technical controls. It does not establish standard NDA wording, a universal liability cap, or required indemnity language for external engineers. Those terms depend on your deal, your sector, and your counsel. Your legal obligations may also come from sector rules, customer requirements, safety requirements, export controls, or privacy laws. This is general information, not legal advice, so have a lawyer read the final contract.
What you can do is write the technical controls into the contract as obligations, so they are enforceable rather than informal. Cover these topics:
- Access controls: unique credentials, strong authentication, role limits, and the access window, matching the controls above.
- Logging rights: your right to collect, keep, and review all session logs.
- Device rules: no use of engineering workstations outside the ICS area, and no vendor devices on the control network.
- Data scope for the NDA: name the specific data in play, such as CAD files and process data, and who at the vendor may see it.
- Testing before production: a sandbox step before any change reaches live systems.
- Liability and indemnity: negotiated amounts and terms, set by counsel for your risk, not copied from a template.
If you are still choosing a vendor, our guide to four routes for hiring forward deployed engineers and the profiles of forward deployed engineering firms help you compare options. Our companion guide on securely granting forward deployed engineers access covers a related setting.
What is the pre-access checklist?
Confirm all of these before the first vendor session:
- Impact level chosen (low, moderate, or high) for each OT area in scope.
- Remote-access points inventoried and the vendor path confined to one enclave.
- Named accounts created, with multifactor authentication and role-based limits.
- Central logging and near-real-time monitoring switched on.
- Sandbox ready for testing changes.
- Contract and NDA terms reviewed by counsel.
Common questions
What is a forward deployed security engineer?
There is no official government definition. In practice it describes an engineer who works near or inside a customer environment to implement, operate, or secure systems. Check each vendor's job scope in the statement of work.
How do forward deployed teams connect to air-gapped manufacturing systems?
A truly air-gapped system cannot be reached over an ordinary network path. Any approved connection needs an explicitly designed transfer or controlled intermediary process, and the sources here do not give a complete onboarding procedure, so design it with your security team.
What compliance certifications should a forward deployed engineering firm hold?
No universal certification list applies to every firm. Requirements depend on your customer, system classification, sector, contract, and whether cloud services are involved. Ask your counsel and customers which ones apply to you.
How do you structure NDAs for external engineers accessing proprietary manufacturing data?
The NIST sources here do not provide standard NDA wording. Name the specific data covered, such as CAD files and process data, list which vendor staff may see it, and have counsel draft the terms.
What are the standard liability clauses when external engineers deploy code to factory floors?
The sources here do not establish a standard liability cap or indemnity clause. Liability terms depend on your deal and risk, so negotiate them with counsel and pair them with technical controls such as sandbox testing before production.
Sources
- NIST SP 800-82 Rev. 3
- NIST SP 800-82 Rev. 3 PDF
- NIST SP 800-82 Rev. 2 PDF
- NIST SP 1800-10
- NIST SP 800-82 Rev. 1 PDF
- NIST announcement for SP 800-82 Rev. 3
- NIST SP 800-82 Rev. 3 initial public draft
Checked when this guide was written. Prices, programs and terms change, so confirm on each page.